Mouse ST2 ELISA Kit
SKU: 67522979309

Mouse ST2 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 7 - Jul 12

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse ST2 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)

2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL

3. 37℃ constant temperature box

4. Distilled water or deionized water

Sample processing and requirements:
Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.

Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.

Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.

Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.

2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.

3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.

4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.

5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.

2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)

3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.

4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).

5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.

6. Washing: Discard the liquid and wash the plate five times as in step 4.

7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.

8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.

2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Syntenin 2 (ST2) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of Syntenin 2 (ST2) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Mouse
Synonym Mouse Syntenin 2 ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Syntenin 2 (ST2), also known as Syntenin-2 or SITAC18, is encoded by the SDCBP2 gene. It is a protein containing two PDZ domains. PDZ domains promote protein-protein interactions by binding to the cytoplasmic C-termini of transmembrane proteins. It exists in two alternatively spliced variants, 2α and 2β, which differ in the length of their N-terminal regions. It binds phosphatidylinositol 4,5-bisphosphate (PIP2) and plays a role in nuclear PIP2 organization, cell division, and cell survival.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.156-10 ng/mL
Applications Serum, plasma, tissue homogenates and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 67522979309

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.6 ★★★★★
Based on 2365 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
Michael
Charlottesville, US
★★★★★ 4
Almost Perfect
If you’ve ever seen these things, the foldable ones are just as good as the standard ones. I just wish when you folded it up there was a way to lock it into that position. When you unfold it to play, you lock it into place with the orange locking slide so it doesn’t fold up on you. But when you’re done playing and fold it up, there’s no way to lock it into that position, it can keep unfolding if you carry it around with you, plus the orange locking slide keeps sliding up and down. It’s not a huge deal, but they could’ve made it better.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 29, 2026
S
Verified Purchase
SC
Dallas, US
★★★★★ 5
Helpful
I’ve used Chuckit ball launchers, this one is foldable, great for my back pack when camping with my dog
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 27, 2026
C
Verified Purchase
capriceclassic
Birmingham, US
★★★★★ 5
Awesome for hyper dogs
Color: Blue
AWESOME - I have a dog that just won't stop trying to get me to play with him ALL day! I turn this thing on and he goes nuts and tires himself out...without any help from me. The cover got torn off and torn up in minutes but he doesn't care. He just wants this ball. My other dogs, who are older, aren't really interested. But if you have a hyper dog this is the thing for you and them!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2026
S
Verified Purchase
Shannon
Fort Morgan, US
★★★★★ 5
Great entertainment, charges quickly!
Color: Orange
Super fun entertainment for dog! Toy ball charges quickly and the charge lasts for at least an hour of playtime for the dog. There are 2 modes. one mode Just lights up, which makes it easy for pet to chase it. The second mode not only lights up, but it also wiggles on the ground Randomly and speeds off in a direction on its own, which really makes it interesting for your dog or cat to follow! Once the ball is not touched for about thirty seconds, it goes dormant and it will stay like that As long as it's charged until somebody touches it, and then it starts up randomly lighting up and moving around the floor on its own And making a vibration noise. It's a lot of fun to watch the dog chase and play with, and it certainly keeps them entertained for a while! The laughs and fun entertainment are definitely worth it. The only downside is that my dog chewed off the soft fabric covering in about twenty minutes.And she's not a real big chewer. It looks better with the covering on it, but even without it, the ball works fine and she plays with it every day.So that is not a showstopper. But good to supervise your dog for safety.In case they are a chewer, and they decide to destroy the cover. But the ball works fine without the cover too!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 12, 2026
S
Verified Purchase
Shanna S.
New York, US
★★★★★ 4
Looooves her crazy new ball
Color: Orange, Color: Orange
Our 90lb mastiff/boxer mix Indie is very playful, curious and energetic. She needs toys that engage her and keep her busy. This ball does the job! We’ve had it for less than a week. Here’s what I love and what could be better: PROS: • She dog loves it. She whines for it. She gets absurdly excited when I get it out. She’s a bit of an anxious dog, but had zero problems with it inexplicably coming to life. • It lasts a while on a single charge, so it keeps her busy for a good long time. The longest we’ve used it at a stretch is an hour. • It’s pretty durable. She’s a super chewer (destroyed every “non-destructible” toy we’ve purchased for her), but the actual ball is hard plastic. She gnaws on it and it gets scratches, for sure. But she’s not going to chew it to pieces. • On carpet, it’s reasonably quiet. • It comes with a replaceable silicone button. • It’s easy to charge…just pull off the silicone button and the charging port is inside. • The silicone button is flush with the ball’s hard plastic surface, so there’s no way for her to pull the silicone button out and swallow it or get to the charging port. CONS: • Cover is worthless if your dog is a chewer. It goes on like an envelope with a Velcro closure. We took it off immediately. • Without the cover, it’s very noisy on hardwood floors. To us, it’s worth it. (Though, I work from home, so I might feel differently after the holiday vacation.) • She’s an XL dog, so she can fit the whole ball in her mouth easily and accidentally chomp down on the button and turn the ball off. Not a big deal, just something to know if you’ve got a Lab or larger dog. • With extended playtime, the two halves can come unscrewed, especially with a large dog who uses their paws/jaws on it a lot. Thankfully, it makes a loud buzzing noise when this happens, so we know we need to take it from her and screw it back together. Is this a potential danger? With the rechargeable battery inside, I’d say yes. But we also don’t let her play with this toy without supervision. So keep that in mind. Bottom line: It has its drawbacks, but it keeps her entertained and seems like it should last her at least 6 months with supervised play. Which is honestly REALLY good when we’re talking about Indie, Destroyer of Toys. I’d buy it again.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 31, 2024

recommand products